Sign In

  • Forgot your password?
  • Need a new account?

Register


NIR-SPD-900-1700

Gated; wavelength range:900-1700nm; efficiency@1550 nm:10% 15% 20%(default) 25%(±1%);External Trigger Frequency:1~100MHz Gate Width:Typ:1ns

MODEL:NIR-SPD-900-1700

$10541.00 Contact us Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
NIR-SPD-900-1700-FR-CDZ
Free running; wavelength range:900-1700nm; efficiency:~30%@1550nm; Dark count rate:< 1.2k cps@25%PDE
Contact us Request for quote
NIR-SPD-900-1700-FR-DZ
Free running; wavelength range:900-1700nm; efficiency:~30%@1550nm; Dark count rate:< 2k cps@25%PDE
Contact us $25021.00
NIR-SPD-900-1700-FR
Free running; wavelength range:900-1700nm; efficiency:~30%@1550nm; Dark count rate:< 5k cps@30%PDE
Contact us $18321.00

Compatible

Compare Model Drawings & Specs Availability Reference Price

 

Product Specifications and Brochures

Product Brochure Link: 

 

Technical Parameters
Detection wavelength range 900~1700nm
External trigger frequency 1-100MHz
Gated width 1ns typ.
Effective width of detection[1] 170ps typ.
Single photon detection efficiency[2] 10% 15% 20%(default) 25% (±1%)
(30% per request)
Dark count rate STD: ≤ 6.0e-6/gate @ 20%SPDE
ULN: ≤ 0.5e-6/gate @ 20%SPDE
Posterior pulse probability@50MHz ≤ 1% @10%SPDE
≤ 2% @20%SPDE
≤ 5% @25%SPDE
Cooling time ≤ 5min
Dead time adjustment 0-1000 clocks
Other parameters
Recommended operating temperature[3] -10~35
Limit operating temperature[4] -15~40
Supply voltage 11.5V~12.5VDC
Power dissipation Maximum cooling power consumption <36W
Stable maximum power consumption <15W
Dimension (WxDxH) 72.4 x 152 x 57.5 mm
Weight 0.95Kg

Note:
[1]The detection count drops to half of the photon count peak corresponding to the gated to photon relative time width.
[2]Single photon detection efficiency calibrated at 1550nm wavelength at room temperature 25
°C.
[3]SPAD cooling works normally, and the photon count fluctuation range does not exceed 20% of the calibrated value.
[4]SPAD cooling works normally, and the photon count fluctuation range does not exceed 50% of the calibrated value.

 

NIR-SPD-900-1700 - Parameter

NIR-SPD-900-1700-FR-CDZ - Parameter

NIR-SPD-900-1700-FR-DZ - Parameter

NIR-SPD-900-1700-FR - Parameter

NIR-SPD-900-1700 - Download

NIR-SPD-900-1700-FR-CDZ - Download

NIR-SPD-900-1700-FR-DZ - Download

NIR-SPD-900-1700-FR - Download